Laboratory Services
Urinalysis, Dipstick
Print this pageUpdated Test Information:
Test Description |
Urinalysis, Dipstick
|
|||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Synonym(s) |
UDIP, UA |
|||||||||||||||||||||||||
Test ID |
UDIP
|
|||||||||||||||||||||||||
General Information |
Detect abnormalities of urine; diagnose and manage renal diseases, urinary tract infection, urinary tract neoplasms, systemic diseases, and inflammatory or neoplastic diseases adjacent to the urinary tract |
|||||||||||||||||||||||||
Specimen Type |
Urine |
|||||||||||||||||||||||||
Specimen Requirements |
Urine Cup |
|||||||||||||||||||||||||
Minimum Sample Volume |
5 ml of urine |
|||||||||||||||||||||||||
Pediatric Min. Volume (if applicable) |
2 ml of urine |
|||||||||||||||||||||||||
Additional Processing Details |
If analysis is unable to be performed within one hour of collection, store refrigerated up to 24 hours. |
|||||||||||||||||||||||||
Stability |
1 hour room temperature. |
|||||||||||||||||||||||||
Unacceptable Specimen Conditions |
Quantity not sufficient; improper labeling; specimen received in inappropriate preservative; specimen received in urine cup stored at room temperature greater than 1 hour old; specimen received in urine cup refrigerated more than 24 hours old; frozen specimens; specimens received in BD Vacutainer UA Preservative Tube more than 48 hours old |
|||||||||||||||||||||||||
Limitations |
Metabolites of Pyridium® may interfere with the dipstick reactions by producing color interference. High vitamin C intake may cause an underestimate of glucose, blood, bilirubin, and a false-negative nitrite test. A low ph can also result in a false negative for protein and WBC's. A false negative for WBC's also can occur with elevated specific gravity, glucose, and/or protein levels. An increased specific gravity may cause a false negative for blood and/or nitrites. False positives can occure for protein when hemoglobin is present and/or an elevated ph level. |
|||||||||||||||||||||||||
Methodology |
Automated |
|||||||||||||||||||||||||
Estimated TAT |
0-2 days |
|||||||||||||||||||||||||
Testing Schedule |
Monday-Saturday |
|||||||||||||||||||||||||
CPT Code(s) |
81003 |
|||||||||||||||||||||||||
Reference Range |
|
|||||||||||||||||||||||||
Performing Lab |
Incyte Diagnostics |
|||||||||||||||||||||||||
LOINC Code(s) |
24357-6 |
|||||||||||||||||||||||||
Additional Information |
Includes: |